EXCEL Chimney
Insulated Length (EL)
EXCEL chimney lengths are available in 48”, 24”, 18”, 12” & 6” lengths. To determine the installed length deduct 1 1/2” from the overall length.
Insulated Adjustable Length (ELA18)
This unique part enables an installer to adjust the system to the exact overall length required for any installation. The most common applications for the adjustable length are: – Between elbows so that any required centre-to-centre offset can be achieved. – When it is necessary to balance the chimney height so that the caps line up for functional or aesthetic reasons. – When a specific horizontal offset is required. The adjustable length must be installed above a straight chimney length. It will not adjust into an elbow or tee. – Adjustable lengths must be installed above a fixed length or they will not be adjustable. If they are installed immediately above a support, tee or elbow they will not adjust. To determine the installed length deduct 1 1/2” from the overall length.
Excel Liner
Length (LL4; LL3; LL2; LL1)
EXCELiner is available in 4’, 3’, 2’ and 1’ lengths. EXCELiner components fasten together with 100% stainless steel pop rivets wich are supplied with the liner. The holes and slots for the rivets are factory pre-punched so no drilling is required. The male and female ends are hemmed to make the liner more rigid and reduce the likelihood of cutting yourself during installation.
Slip Length (LLA3; LLA1)
Slip lengths are available in 3’ and 1’ lengths. Slip lengths are used to adjust the length of the system without cutting. Note: Slip lengths must be installed above a fixed length or they will not adjust. They should not be installed immediately above a support, tee or elbow.
Split Base Tee (LT)
The flange for the tee mouth is formed into the vertical tee body to provide a strong connection while minimizing projection to facilitate installation in tight flues. The tee mouth fastens to the body with heavy duty stainless steel screws which install through the inside of the mouth.
Download ICC catalogue |
Excel pellet venting
3” to 4” Stove Adapter Tee (3PAT3; 3PAT3B; 3PAT4; 3PAT4B)
3” to 4” Stove Adapter Tee
3” – 4” Tapered Increaser (3PIT4; 3PIT4B)
Inline increaser is recommended for systems that have long runs. Available in Galvalume or Black exterior.
Flex Adapter Tee (PATF)
For pellet stove installations that are vented into a masonry chimney. Connects EXCELPellet to a 4” flexible liner and has a removable twist mouth that is available in 3” or 4”. Use in combination with the Masonry Adapter (PAM).
Download ICC catalogue |
Excel prime single wall pipe
Length (SW) – Slip Length (SW1S)
Lengths are available in 12”, 18”, 24”, 36” and 48” lengths; 6”, 7” and 8” diameter.
Fabricated from heavy wall 22ga satincoat steel. Each length is laser welded for unparalleled fit and finish. There are no unsightly beads or bumps on the exterior.
Slip Lengths will slide into a regular straight length allowing you to adjust the overall length of a straight run without cutting. The minimum adjustment can be reached only if the length used below the slip length is long enough to accept it.
Adjustable Length (SWA)
The Adjustable Length (SWA) combines a 36” length and a 36” slip length in one box. The SWA provides enough range that it is often the only component required for vertical installations.
Tee (SWT)
Combines a 90° transition with a clean out. Does not include a Tee Cap (SWTP).
Download ICC catalogue | Download EXCEL Prime |
Ultra black double wall pipe
Length (UB)
Are available in 5”, 12”, 18”, 24” and 36”.
Adjustable Length (UBAF)
Combines a 36” length and a 36” slip length in one box. The UBAF fits all brands of insulated chimney and most brands of wood burning stoves without a stove or chimney adapter. A UBTC trim collar is included with the UBAF.
Slip Length (UB6SF; UB12SF; UB18SF)
These lengths slide over a regular straight length allowing you to adjust the overall length of a straight run without cutting. The minimum adjustment can be reached only if the length used below the slip length is long enough to accept it.